Interior Materials and Components
Page:  1 of 10
Printed copies are uncontrolled
qq外观Official Record Series 25.01, © Jaguar Land Rover Limited
INDEX
A  Index
B  Scope
C  Object
D  Review
E  Related Documents
F  Requirements  Z
Change History
SCOPE
Applicable to all surface materials in the interior of the vehicle with a surface area exceeding 100 cm 2 (all colours) and components that may affect the cabin odour. Trim, adhesives, sealants, final
production materials and the specific components are required to meet this standard.
OBJECT
The purpose of this standard is to ensure that our vehicle interiors meet the continuing demand for
reduced Volatile Organic Compounds (VOC) and hazardous material emissions.
REVIEW
This document is to be reviewed every three years from the date of the last review or update.
保时捷macan2020新款RELATED DOCUMENTS高尔夫蓝驱版
TPJLR.52.095 TPJLR.52.104 TPJLR.52.107 TPJLR.52.109 TPJLR.52.112 TPJLR.52.113
TPJLR.52.458 STJLR.99.9999 SAE J1756
TÜV TOXPROOF Criteria Catalogue VDA 277 ISO 16000-6汽车保险费用
Interior Materials and Components Page:  2 of 10 REQUIREMENTS
All materials and components must comply with Jaguar Land Rover's restricted substance management requirements, STJLR.99.9999.
1 Requirements for materials
∙Applicable to all surface materials, (e.g. leathers, PVCs, painted plastics), NVH materials, adhesives, sealants, carpets, seat foams, surface-mounted components and laminar
materials (e.g. veneers, parcel trays, load floor, headlining) used in the vehicle cabin;
∙All colours are required to be tested;
奥迪r8提车作业∙Eight A5 samples for hard trim materials, or 0.5 m2 of soft trim materials are required;
∙Hard trim samples shall be provided in plaque form (in certain cases, where the component meets the dimensional requirements of the test apparatus, components may be analysed);
∙Materials shall be analysed before <VP> gateway;
∙Components shall be tested before <FEC> gateway;
∙Submitter is responsible to provide samples 4 weeks before the relevant deadlines;
∙Submitter is responsible to provide detailed information (e.g. material type, grade, production date, c
olour, etc.) about the sample.
Trim materials
∙Trim materials samples must be tested for odour (TPJLR.52.458), fogging (SAE J1756), total VOCs emissions (VDA 277) and specific compounds emissions
(TPJLR.52.104 - µ-chamber method or TPJLR.52.095 – 10 litre bag method);
∙Table 1 shows the limits for odour, fogging and total VOCs.
Table 1: Odour, fogging and total VOCs limits for trim materials
(1)…16 hours at 100°C ± 2°C; with 21°C ± 2°C cooling plates; 4 hours post-test conditioning; If the
fogging value exceeds 2.5 mg, a photometric measurement must be done. The photometric
value (3 hours at 100°C ± 2°C, 21 °C ± 2°C cooling plates; 1 hour and 16 hours post-test
conditioning) must not be lower than 70 after 16 hours.
Interior Materials and Components Page:  3 of 10
∙If the sample geometry is not suitable for specific compounds emissions determination according to TPJLR.52.104, the sample must be analysed according to TPJLR.52.095;
∙Identification and quantification of target VOCs must be done according to ISO 16000-6;
∙Materials are divided into groups (A-C) according to Table 2;
∙Materials not specified in Table 2 must be evaluated as Group A.
Table 2: Material groups for specific compounds emissions evaluation
∙Table 3 shows the compound emission limits for individual groups tested according to TPJLR.52.104.
Table 3: Compound emission limits for material groups tested according to TPJLR.52.104
Interior Materials and Components Page:  4 of 10
4月汽车销量排行榜
Table 4 shows the compound emission limits for individual groups tested according to TPJLR.52.095.
Table 4: Compounds emission limits for material groups tested according to TPJLR.52.095
CMR = carcinogen (C), mutagen (M), toxic to reproduction (R) according to classification in annex
VI of REGULATION (EC) No. 1272/2008 (GHS) and additionally according to national classification following TRGS 905 or MAC (maximum allowable concentration) and BAT data list (biological limit
of tolerance for substances)
Substances of acute toxicity or with specific target organ toxicity according to annex VI of REGULATION (EC) No. 1272/2008 (GHS) or categorized as very toxic (T+) or Hazardous Substances Ordinance (GefStoffV).
Respiratory sensitisers cat. 1 and skin sensitisers cat. 1 acc. to annex VI of REGULATION (EC) No
1272/2008 (GHS) or substances classified as sensitisers acc. to TRGS 907 or MAC (maximum allowable concentration) and BAT data list (biological limit substances)
Intentionally Blank
Interior Materials and Components Page:  5 of 10
1.2 Adhesives and sealants
∙Adhesives and sealants samples must be tested for total VOCs emissions (VDA 277) and specific compounds emissions (TPJLR.52.095 – 10 litre bag method);
∙Table 5 shows the limits for total VOCs emissions.
Table 5: Total VOCs limits for adhesives and sealants
∙Identification and quantification of target VOCs must be done according to ISO 16000-6;
∙Specific compound emission limits are stated in Table 6.
Table 6: Specific compound emission limits for adhesives and sealants tested according to
TPJLR.52.095 (10 litre bag method)